{"id":46256,"date":"2025-06-23T03:26:49","date_gmt":"2025-06-23T03:26:49","guid":{"rendered":"https:\/\/luxmanlight.com\/?p=46256"},"modified":"2025-06-23T03:31:24","modified_gmt":"2025-06-23T03:31:24","slug":"street-light-distribution-analysis-how-to-meet-your-road-lighting-standards","status":"publish","type":"post","link":"https:\/\/luxmanlight.com\/th\/street-light-distribution-analysis-how-to-meet-your-road-lighting-standards\/","title":{"rendered":"Street Light Distribution Analysis &#8211; How to Meet Your Road Lighting Standards!"},"content":{"rendered":"<p>This is a requirement for <a href=\"https:\/\/luxmanlight.com\/th\/%e0%b8%81%e0%b8%b2%e0%b8%a3%e0%b8%ad%e0%b8%ad%e0%b8%81%e0%b9%81%e0%b8%9a%e0%b8%9a%e0%b8%a3%e0%b8%b0%e0%b8%9a%e0%b8%9a%e0%b9%84%e0%b8%9f%e0%b8%96%e0%b8%99%e0%b8%99%e0%b8%9e%e0%b8%a5%e0%b8%b1%e0%b8%87\/\">road lamp design.<\/a><\/p>\n<div style=\"overflow-x: auto;\">\n<table data-v-md-line=\"3\">\n<thead>\n<tr>\n<th>Item Name<\/th>\n<th>Route Code<\/th>\n<th>Road Width (m)<\/th>\n<th>Surface Type<\/th>\n<th>Lamp Configuration<\/th>\n<th>Number of Lamps<\/th>\n<th>Lamp Height (m)<\/th>\n<th>Lamp Spacing (m)<\/th>\n<th>Angle (\u00b0)<\/th>\n<th>Length of Lamp Arm (m)<\/th>\n<th>Distance Between Lamp and Road (m)<\/th>\n<th>Illuminance (1m)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Route 1<\/td>\n<td>M5<\/td>\n<td>7m<\/td>\n<td>CIE C2 (Calculated Humidity)<\/td>\n<td>Unilateral Lamp<\/td>\n<td>0.8<\/td>\n<td>12<\/td>\n<td>40<\/td>\n<td>0<\/td>\n<td>0<\/td>\n<td>0.75<\/td>\n<td>8000<\/td>\n<\/tr>\n<tr>\n<td>Route 2<\/td>\n<td>M3<\/td>\n<td>14m<\/td>\n<td>CIE C2 (Calculated Humidity)<\/td>\n<td>Bilateral Lamp<\/td>\n<td>0.8<\/td>\n<td>10<\/td>\n<td>40<\/td>\n<td>0<\/td>\n<td>0<\/td>\n<td>0.75<\/td>\n<td>8000<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Now, based on the above conditions, we need to select the light distribution for the lamps and verify it.<\/p>\n<p>First, let&#8217;s analyze the road conditions.<\/p>\n<p>For Route 1, with a road width of 7m, this should be a two-lane road with unilateral lamp arrangements, pole spacing of 40m, and pole height of 7.5m.<\/p>\n<p>For Route 2, with a road width of 14m, this should be a four-lane, bidirectional road with bilateral lamp arrangements, pole spacing of 40m, and pole height of 9m.<\/p>\n<p>Based on these road conditions, we proceed with the selection of light distribution, referencing IESNA&#8217;s categorization of street lamps.<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-46285 size-full aligncenter\" src=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-14.png\" alt=\"IESNA Street Lamp Classification\" width=\"841\" height=\"714\" srcset=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-14.png 841w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-14-300x255.png 300w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-14-768x652.png 768w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-14-14x12.png 14w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-14-705x599.png 705w\" sizes=\"(max-width: 841px) 100vw, 841px\" \/><\/p>\n<p>\u2191 IESNA Street Lamp Classification, North American Lighting Manual 10th Edition<\/p>\n<p>For one to two-lane roads, we typically choose Type II street lamps. Type I is suitable for paths and sidewalks, while Type III applies to main highways.<\/p>\n<p>We can refer to the following rules based on road width.<\/p>\n<p><img decoding=\"async\" class=\"wp-image-46288 size-large aligncenter\" src=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-1030x281.png\" alt=\"Road Width Light Distribution Guidance\" width=\"1030\" height=\"281\" srcset=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-1030x281.png 1030w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-300x82.png 300w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-768x210.png 768w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-18x5.png 18w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-705x193.png 705w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640.png 1080w\" sizes=\"(max-width: 1030px) 100vw, 1030px\" \/><\/p>\n<p>As per the above table, we should select the Type II L distribution. However, considering the distance of 0.75m between the lamp and the road as specified in the road conditions, we will adjust our pole spacing slightly and choose Type II M or S distribution.<\/p>\n<p><img decoding=\"async\" class=\"wp-image-46290 size-full aligncenter\" src=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-1.png\" alt=\"Type II Light Distribution Test\" width=\"373\" height=\"633\" srcset=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-1.png 373w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-1-177x300.png 177w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-1-7x12.png 7w\" sizes=\"(max-width: 373px) 100vw, 373px\" \/><\/p>\n<p>Let\u2019s begin testing Route 1 by setting the road conditions in DIALux evo (we avoid DIALux4.13 as it does not support the EN13201:2015 standard necessary for selecting the new standard).<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-46291 size-full aligncenter\" src=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-2.png\" alt=\"DIALux evo Road Setting\" width=\"770\" height=\"525\" srcset=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-2.png 770w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-2-300x205.png 300w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-2-768x524.png 768w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-2-18x12.png 18w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-2-705x481.png 705w\" sizes=\"(max-width: 770px) 100vw, 770px\" \/><\/p>\n<p>Here, we need to select the surface type as CIE C2 and check the option for calculating wet road surfaces, choosing W1.<\/p>\n<p>The CIE C2 surface corresponds to asphalt, similar to the reflectivity of our traditional R3. Further explanation of the codes is provided below:<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-46295 size-full aligncenter\" src=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-4.png\" alt=\"CIE C2 Surface Type Codes\" width=\"358\" height=\"584\" srcset=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-4.png 358w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-4-184x300.png 184w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-4-7x12.png 7w\" sizes=\"(max-width: 358px) 100vw, 358px\" \/><\/p>\n<p>With the road conditions set, we can select the light distribution for verification calculations.<\/p>\n<p>We are going to select a Type II S distribution for verification.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-46297 size-full aligncenter\" src=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-3.png\" alt=\"Type II S Distribution Configuration\" width=\"467\" height=\"467\" srcset=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-3.png 467w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-3-300x300.png 300w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-3-80x80.png 80w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-3-12x12.png 12w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-3-36x36.png 36w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-3-180x180.png 180w\" sizes=\"(max-width: 467px) 100vw, 467px\" \/><\/p>\n<p>Set the lamp arrangement conditions and configure the lamp luminous flux to the required 5500lm.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-46295 size-full aligncenter\" src=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-4.png\" alt=\"Lamp Configuration Settings\" width=\"358\" height=\"584\" srcset=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-4.png 358w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-4-184x300.png 184w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-4-7x12.png 7w\" sizes=\"(max-width: 358px) 100vw, 358px\" \/><\/p>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_80 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">\u0e23\u0e32\u0e22\u0e0a\u0e37\u0e48\u0e2d\u0e1a\u0e17<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">\u0e2a\u0e25\u0e31\u0e1a<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/luxmanlight.com\/th\/street-light-distribution-analysis-how-to-meet-your-road-lighting-standards\/#Verification_Results\" >Verification Results<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/luxmanlight.com\/th\/street-light-distribution-analysis-how-to-meet-your-road-lighting-standards\/#Verification_Results-2\" >Verification Results<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/luxmanlight.com\/th\/street-light-distribution-analysis-how-to-meet-your-road-lighting-standards\/#Verification_Results-3\" >Verification Results<\/a><\/li><\/ul><\/nav><\/div>\n<h2><span class=\"ez-toc-section\" id=\"Verification_Results\"><\/span>Verification Results<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-46303 size-full aligncenter\" src=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-5.png\" alt=\"Verification Results for Type II S Distribution\" width=\"814\" height=\"216\" srcset=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-5.png 814w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-5-300x80.png 300w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-5-768x204.png 768w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-5-18x5.png 18w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-5-705x187.png 705w\" sizes=\"(max-width: 814px) 100vw, 814px\" \/><\/p>\n<p>The results were not satisfactory; the road brightness uniformity was below the standard requirement of 0.5cd\/m\u00b2. However, both Uo and Uow, as well as Ul, significantly exceeded the standard values.<\/p>\n<p>We can conclude that the distribution might be slightly inadequate, but where exactly is it lacking? We need to analyze the brightness calculation grid.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-46306 size-full aligncenter\" src=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-6.png\" alt=\"Brightness Calculation Grid Analysis\" width=\"1080\" height=\"313\" srcset=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-6.png 1080w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-6-300x87.png 300w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-6-1030x299.png 1030w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-6-768x223.png 768w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-6-18x5.png 18w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-6-705x204.png 705w\" sizes=\"(max-width: 1080px) 100vw, 1080px\" \/><\/p>\n<p>By analyzing the calculation grid above, we found the minimum value, which is lower between the two lamp poles. This indicates that the light distribution needs to be strengthened at both ends, so we will directly choose Type II M distribution for our calculations.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-46307 size-full aligncenter\" src=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-7.png\" alt=\"Switching to Type II M Distribution\" width=\"467\" height=\"467\" srcset=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-7.png 467w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-7-300x300.png 300w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-7-80x80.png 80w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-7-12x12.png 12w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-7-36x36.png 36w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-7-180x180.png 180w\" sizes=\"(max-width: 467px) 100vw, 467px\" \/><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-46308 size-full aligncenter\" src=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-8.png\" alt=\"Type II M Distribution Settings\" width=\"358\" height=\"575\" srcset=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-8.png 358w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-8-187x300.png 187w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-8-7x12.png 7w\" sizes=\"(max-width: 358px) 100vw, 358px\" \/><\/p>\n<h2><span class=\"ez-toc-section\" id=\"Verification_Results-2\"><\/span>Verification Results<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-46309 size-full aligncenter\" src=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-9.png\" alt=\"Results for Type II M Distribution\" width=\"321\" height=\"210\" srcset=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-9.png 321w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-9-300x196.png 300w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-9-18x12.png 18w\" sizes=\"(max-width: 321px) 100vw, 321px\" \/><\/p>\n<p>The results are all satisfactory, indicating that this light distribution can meet client requirements under the specified 5500lm luminous flux.<\/p>\n<p>Next, let\u2019s look at Route 2 and set the road conditions: a four-lane, bidirectional road, M4 standard, calculated wet surface.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-46310 size-full aligncenter\" src=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-10.png\" alt=\"Route 2 Conditions Setup\" width=\"363\" height=\"603\" srcset=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-10.png 363w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-10-181x300.png 181w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-10-7x12.png 7w\" sizes=\"(max-width: 363px) 100vw, 363px\" \/><\/p>\n<p>The road conditions for Route 2 are essentially the same as Route 1, except it\u2019s a four-lane bidirectional roadway with bilateral lamp arrangements, upgraded by one level.<\/p>\n<p>We will again choose Type II M distribution for arrangement.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-46311 size-full aligncenter\" src=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-11.png\" alt=\"Type II M distribution for Route 2\" width=\"356\" height=\"613\" srcset=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-11.png 356w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-11-174x300.png 174w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-11-7x12.png 7w\" sizes=\"(max-width: 356px) 100vw, 356px\" \/><\/p>\n<h2><span class=\"ez-toc-section\" id=\"Verification_Results-3\"><\/span>Verification Results<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-46312 size-full aligncenter\" src=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-12.png\" alt=\"Results for Route 2 Validation\" width=\"494\" height=\"441\" srcset=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-12.png 494w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-12-300x268.png 300w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/06\/640-12-13x12.png 13w\" sizes=\"(max-width: 494px) 100vw, 494px\" \/><\/p>\n<p>Both sides met the conditions, indicating that this distribution can satisfy client requirements under the specified 6500lm luminous flux.<\/p>\n<p>Through this analysis, it is evident that there are patterns to follow when selecting light distribution for <a href=\"https:\/\/luxmanlight.com\/th\/%e0%b9%84%e0%b8%9f%e0%b8%96%e0%b8%99%e0%b8%99%e0%b8%9e%e0%b8%a5%e0%b8%b1%e0%b8%87%e0%b8%87%e0%b8%b2%e0%b8%99%e0%b9%81%e0%b8%aa%e0%b8%87%e0%b8%ad%e0%b8%b2%e0%b8%97%e0%b8%b4%e0%b8%95%e0%b8%a2%e0%b9%8c-3\/\">street lighting<\/a>. Whether choosing existing products or developing new distributions, one can design according to these rules and then identify defects through calculation results, making targeted modifications accordingly.<\/p>","protected":false},"excerpt":{"rendered":"<p>This is a requirement for road lamp design. Item Name Route Code Road Width (m) Surface Type Lamp Configuration Number [&hellip;]<\/p>\n","protected":false},"author":9,"featured_media":46303,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[34,69],"tags":[],"class_list":["post-46256","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","category-blog-es"],"_links":{"self":[{"href":"https:\/\/luxmanlight.com\/th\/wp-json\/wp\/v2\/posts\/46256","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/luxmanlight.com\/th\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/luxmanlight.com\/th\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/luxmanlight.com\/th\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/luxmanlight.com\/th\/wp-json\/wp\/v2\/comments?post=46256"}],"version-history":[{"count":0,"href":"https:\/\/luxmanlight.com\/th\/wp-json\/wp\/v2\/posts\/46256\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/luxmanlight.com\/th\/wp-json\/wp\/v2\/media\/46303"}],"wp:attachment":[{"href":"https:\/\/luxmanlight.com\/th\/wp-json\/wp\/v2\/media?parent=46256"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/luxmanlight.com\/th\/wp-json\/wp\/v2\/categories?post=46256"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/luxmanlight.com\/th\/wp-json\/wp\/v2\/tags?post=46256"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}