{"id":40825,"date":"2025-05-26T08:37:01","date_gmt":"2025-05-26T08:37:01","guid":{"rendered":"https:\/\/luxmanlight.com\/?p=40825"},"modified":"2025-05-26T08:40:42","modified_gmt":"2025-05-26T08:40:42","slug":"why-calculate-the-luminance-uniformity-of-wet-road-surfaces","status":"publish","type":"post","link":"https:\/\/luxmanlight.com\/ms\/why-calculate-the-luminance-uniformity-of-wet-road-surfaces\/","title":{"rendered":"Why calculate the luminance uniformity of wet road surfaces?"},"content":{"rendered":"<p style=\"text-align: left;\"><strong>Why is it necessary to calculate the luminance uniformity of wet road surfaces?<\/strong><\/p>\n<section>Recently, someone asked me why there are two values of Uo in the road lighting requirements given by the client.<\/section>\n<section><\/section>\n<section>Indeed, why are there two Uo values?<\/section>\n<section><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone wp-image-40846 size-full\" src=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/2025526164021.jpg\" alt=\"Why calculate the luminance uniformity of wet road surfaces?\" width=\"765\" height=\"542\" srcset=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/2025526164021.jpg 765w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/2025526164021-300x213.jpg 300w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/2025526164021-18x12.jpg 18w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/2025526164021-260x185.jpg 260w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/2025526164021-705x499.jpg 705w\" sizes=\"(max-width: 765px) 100vw, 765px\" \/><\/section>\n<section>The road lighting standard we are most familiar with is the CJJ45-2015 &#8220;Design Standard for Urban Road Lighting,&#8221; which is widely used in our country. In this standard, Uo refers to the overall uniformity of road surface luminance.<\/section>\n<section><img decoding=\"async\" class=\"alignnone wp-image-40826 size-full\" src=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640.png\" alt=\"Uo reference image\" width=\"821\" height=\"418\" srcset=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640.png 821w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-300x153.png 300w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-768x391.png 768w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-18x9.png 18w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-705x359.png 705w\" sizes=\"(max-width: 821px) 100vw, 821px\" \/><\/section>\n<section>Moreover, there is only one Uo value in this standard.<\/section>\n<section>So, why does the aforementioned client&#8217;s request include two Uo values?<\/section>\n<section>This leads us to the international standard CIE115\/EN13201.<\/section>\n<section>In the requirements provided by the client, the road classification is A1, which immediately indicates that the applicable road classification standard is EN13201-1:2004. Those who have used DIALux 4.13 should be quite familiar with this standard.<\/section>\n<section>Only in the EN13201:2004 road classification is there an A1 level.<\/section>\n<section><img decoding=\"async\" class=\"alignnone wp-image-40827 size-full\" src=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-1.png\" alt=\"EN13201 A1 level classification\" width=\"1080\" height=\"454\" srcset=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-1.png 1080w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-1-300x126.png 300w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-1-1030x433.png 1030w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-1-768x323.png 768w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-1-18x8.png 18w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-1-705x296.png 705w\" sizes=\"(max-width: 1080px) 100vw, 1080px\" \/><\/section>\n<section>By the time we reach 13201-1:2014, the road classifications have changed completely.<\/section>\n<section><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-40828 size-full\" src=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-2.png\" alt=\"Changes in road classification EN13201-1:2014\" width=\"731\" height=\"354\" srcset=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-2.png 731w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-2-300x145.png 300w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-2-18x9.png 18w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-2-705x341.png 705w\" sizes=\"(max-width: 731px) 100vw, 731px\" \/><\/section>\n<section>The illumination standard corresponding to 13201-1:2014 is EN 13201-2:2003, where the roadway lighting standards are as follows.<\/section>\n<section><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-40829 size-full\" src=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-3.png\" alt=\"Road lighting standard EN 13201-2:2003\" width=\"785\" height=\"483\" srcset=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-3.png 785w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-3-300x185.png 300w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-3-768x473.png 768w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-3-18x12.png 18w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-3-705x434.png 705w\" sizes=\"(max-width: 785px) 100vw, 785px\" \/><\/section>\n<section>Wait, there is still only one overall luminance uniformity Uo. So, where is the other Uo? Don\u2019t worry, if we look closely at the table, it specifies dry road surface conditions, which means there is also a standard for wet road surfaces.<\/section>\n<section><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-40830 size-full\" src=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-4.png\" alt=\"Dry vs. Wet road surface standards\" width=\"738\" height=\"443\" srcset=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-4.png 738w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-4-300x180.png 300w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-4-18x12.png 18w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-4-705x423.png 705w\" sizes=\"(max-width: 738px) 100vw, 738px\" \/><\/section>\n<section>Correct, the standard level for a dry roadway surface is ME, while the standard for a wet roadway surface is MEW, where the &#8220;W&#8221; stands for wet.<\/section>\n<section><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-40831 size-full\" src=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-5.png\" alt=\"Standard levels for dry and wet surfaces\" width=\"905\" height=\"406\" srcset=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-5.png 905w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-5-300x135.png 300w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-5-768x345.png 768w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-5-18x8.png 18w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-5-705x316.png 705w\" sizes=\"(max-width: 905px) 100vw, 905px\" \/><\/section>\n<section>In this table, we find two Uo values: one for dry conditions with a minimum Uo value of no less than 0.4 and another for wet conditions with a minimum Uo value of no less than 0.15.<\/section>\n<section><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-40832 size-full\" src=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-6.png\" alt=\"Uo values for dry and wet road conditions\" width=\"1080\" height=\"574\" srcset=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-6.png 1080w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-6-300x159.png 300w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-6-1030x547.png 1030w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-6-768x408.png 768w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-6-18x10.png 18w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-6-705x375.png 705w\" sizes=\"(max-width: 1080px) 100vw, 1080px\" \/><\/section>\n<section>Since this is based on the EN13201-2:2003 standard, it means that illumination calculations can be completed using DIALux 4.13, which integrates the road lighting standards from 13201-2:2003. If using the 2015 version, DIALux evo would be required.<\/section>\n<section>Now let\u2019s try to calculate the lighting for this road according to the conditions.<\/section>\n<section><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-40833 size-full\" src=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-7.png\" alt=\"Initial road lighting calculation setup\" width=\"1080\" height=\"572\" srcset=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-7.png 1080w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-7-300x159.png 300w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-7-1030x546.png 1030w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-7-768x407.png 768w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-7-18x10.png 18w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-7-710x375.png 710w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-7-705x373.png 705w\" sizes=\"(max-width: 1080px) 100vw, 1080px\" \/><\/section>\n<section>According to client requirements, select the new street design case in the English interface, and then set the road conditions.<\/section>\n<section><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-40834 size-full\" src=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-8.png\" alt=\"Road condition settings in DIALux\" width=\"1080\" height=\"1080\" srcset=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-8.png 1080w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-8-300x300.png 300w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-8-1030x1030.png 1030w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-8-80x80.png 80w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-8-768x768.png 768w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-8-12x12.png 12w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-8-36x36.png 36w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-8-180x180.png 180w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-8-705x705.png 705w\" sizes=\"(max-width: 1080px) 100vw, 1080px\" \/><\/section>\n<section>After setting the road conditions, select the luminaire photometric distribution. Based on the four-lane dual-directional road width, we prioritize Type III distribution and select either M or S distribution based on the ratio of pole spacing to pole height.<\/section>\n<section><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-40835 size-full\" src=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/6401.jpg\" alt=\"Luminaire photometric distribution selection\" width=\"1080\" height=\"612\" srcset=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/6401.jpg 1080w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/6401-300x170.jpg 300w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/6401-1030x584.jpg 1030w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/6401-768x435.jpg 768w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/6401-18x10.jpg 18w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/6401-705x400.jpg 705w\" sizes=\"(max-width: 1080px) 100vw, 1080px\" \/><\/section>\n<section>\u2191 This distribution is provided by DARKOO, featuring a glass lens material.<\/section>\n<section><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-40836 size-full\" src=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-9.png\" alt=\"Importing selected luminaire distribution files\" width=\"936\" height=\"898\" srcset=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-9.png 936w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-9-300x288.png 300w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-9-768x737.png 768w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-9-13x12.png 13w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-9-36x36.png 36w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-9-705x676.png 705w\" sizes=\"(max-width: 936px) 100vw, 936px\" \/><\/section>\n<section>Import the selected luminaire photometric file and arrange the luminaires as per the client\u2019s requirements.<\/section>\n<section><\/section>\n<section>Set the lighting standards and verify if the standard values match the requirements.<\/section>\n<section>Set the optimization conditions and proceed with the optimization.<\/section>\n<section><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-40837 size-full\" src=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-10.png\" alt=\"Optimization settings in DIALux\" width=\"936\" height=\"898\" srcset=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-10.png 936w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-10-300x288.png 300w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-10-768x737.png 768w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-10-13x12.png 13w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-10-36x36.png 36w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-10-705x676.png 705w\" sizes=\"(max-width: 936px) 100vw, 936px\" \/><\/section>\n<section><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-40838 size-full\" src=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-11.png\" alt=\"Optimized results display\" width=\"936\" height=\"898\" srcset=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-11.png 936w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-11-300x288.png 300w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-11-768x737.png 768w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-11-13x12.png 13w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-11-36x36.png 36w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-11-705x676.png 705w\" sizes=\"(max-width: 936px) 100vw, 936px\" \/><\/section>\n<section>The optimization results indicate that the Over hang between 1-2m satisfies the requirements. We will choose the shortest Over hang to save on pole material.<\/section>\n<section>Import the results and calculate the final outcome.<\/section>\n<section><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-40839 size-full\" src=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-12.png\" alt=\"Final results of the lighting calculation\" width=\"1080\" height=\"459\" srcset=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-12.png 1080w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-12-300x128.png 300w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-12-1030x438.png 1030w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-12-768x326.png 768w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-12-18x8.png 18w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-12-705x300.png 705w\" sizes=\"(max-width: 1080px) 100vw, 1080px\" \/><\/section>\n<section><\/section>\n<section>This yields the calculation results that meet the client\u2019s conditions, allowing us to export the report.<\/section>\n<section>At this point, some may question why there are no requirements for wet road surfaces in domestic road lighting standards. Is it necessary to calculate for wet surfaces?<\/section>\n<section>Actually, the &#8220;CJJ 45-2015 Design Standard for Urban Road Lighting&#8221; mentions that \u201cthe illumination indicators under dry conditions do not meet those under wet conditions. For instance, the overall uniformity of brightness, where a dry condition Uo of 0.4 makes it very difficult to reach 0.2 under wet conditions, yet no standard values for wet road surfaces are given.<\/section>\n<section>The road surface standards in CIE115\/EN13201 are set in accordance with CIE 47-1979 &#8220;Road Lighting for Wet Conditions.&#8221; This standard includes 4 tables in the R series, 4 in the N series, 2 in the C series, and 4 in the W series, to meet rough road surface luminance calculation needs.<\/section>\n<section>However, most of these standard data tables originate from studies conducted by European scientists in the 1960s and 1970s on typical road materials of that time, which differ significantly from the road materials currently in widespread use in China. Due to the lack of research on the reflective characteristics of road materials domestically, there is currently no standard reflectance data for road materials in China. Thus, our domestic standards have not set illumination standards for wet road surfaces.<\/section>\n<section>Of course, this does not imply that the illumination indicators for wet road surfaces are unimportant; in fact, they are quite crucial.<\/section>\n<section><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-40840 size-full\" src=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-13.png\" alt=\"Importance of wet road surface illumination\" width=\"863\" height=\"818\" srcset=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-13.png 863w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-13-300x284.png 300w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-13-768x728.png 768w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-13-13x12.png 13w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-13-705x668.png 705w\" sizes=\"(max-width: 863px) 100vw, 863px\" \/><\/section>\n<section><\/section>\n<section>As shown in the above image, the last image&#8217;s luminance uniformity for wet road surfaces differs greatly from that of dry road surfaces, significantly affecting drivers.<\/section>\n<section>Friends who have driven on rainy nights should all have the experience that the visibility on rainy roads is indeed very poor.<\/section>\n<section><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-40841 size-full\" src=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-11.jpg\" alt=\"Visibility on wet roads during rain\" width=\"1080\" height=\"693\" srcset=\"https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-11.jpg 1080w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-11-300x193.jpg 300w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-11-1030x661.jpg 1030w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-11-768x493.jpg 768w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-11-18x12.jpg 18w, https:\/\/luxmanlight.com\/wp-content\/uploads\/2025\/05\/640-11-705x452.jpg 705w\" sizes=\"(max-width: 1080px) 100vw, 1080px\" \/><\/section>\n<section>Thus, there should be standards for road surface illumination indicators for wet conditions.<\/section>","protected":false},"excerpt":{"rendered":"<p>Why is it necessary to calculate the luminance uniformity of wet road surfaces? Recently, someone asked me why there are [&hellip;]<\/p>\n","protected":false},"author":9,"featured_media":40841,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[34],"tags":[],"class_list":["post-40825","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/luxmanlight.com\/ms\/wp-json\/wp\/v2\/posts\/40825","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/luxmanlight.com\/ms\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/luxmanlight.com\/ms\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/luxmanlight.com\/ms\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/luxmanlight.com\/ms\/wp-json\/wp\/v2\/comments?post=40825"}],"version-history":[{"count":0,"href":"https:\/\/luxmanlight.com\/ms\/wp-json\/wp\/v2\/posts\/40825\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/luxmanlight.com\/ms\/wp-json\/wp\/v2\/media\/40841"}],"wp:attachment":[{"href":"https:\/\/luxmanlight.com\/ms\/wp-json\/wp\/v2\/media?parent=40825"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/luxmanlight.com\/ms\/wp-json\/wp\/v2\/categories?post=40825"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/luxmanlight.com\/ms\/wp-json\/wp\/v2\/tags?post=40825"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}